Indiquez vos coordonnées pour télécharger le document.
Le fichier s’ouvre dans Google Drive : vous pouvez le télécharger ou l’imprimer.
A microbiological analysis measures the presence or number of micro-organisms in a food, on a surface or in a process. In the food industry, its result is read against the criteria of Regulation (EC) 2073/2005 and your own requirements.
It is a laboratory test that detects or counts micro-organisms: pathogenic bacteria (Listeria monocytogenes, Salmonella), hygiene indicators (Enterobacteriaceae, E. coli, aerobic colony count) or toxins. The result is expressed as presence or absence in a test portion (for example 25 g), or in colony-forming units per gram (cfu/g).
Operators use it to validate and verify their control system, not to replace it. The regulation says so explicitly: testing is carried out when operators validate or verify the correct functioning of their procedures based on HACCP principles.
“Food business operators shall perform testing as appropriate against the microbiological criteria set out in Annex I, when they are validating or verifying the correct functioning of their procedures based on HACCP principles and good hygiene practice.”Regulation (EC) No 2073/2005, Article 4(1) · EUR-Lex
The distinction determines everything else: who decides, what is assessed and the consequence of an exceedance.
| Food safety criterion | Process hygiene criterion | |
|---|---|---|
| What it assesses | The acceptability of a product or batch | How the production process is working |
| Where it applies | Products placed on the market, during their shelf life | At a defined stage of production; not to products placed on the market |
| Examples (Annex I) | Listeria monocytogenes, Salmonella, staphylococcal enterotoxins, Cronobacter in infant formulae | Enterobacteriaceae, E. coli, aerobic colony count, coagulase-positive staphylococci |
| In the event of an unsatisfactory result | Withdrawal or recall of the product or batch (Article 7(2)) | Corrective actions set out in Chapter 2 of Annex I (Article 7(4)) |
Source: Regulation (EC) 2073/2005, Articles 2 and 7, Annex I.
An exceedance on a process hygiene criterion does not, on its own, allow a conclusion on a product's compliance, as the French Ministry of Agriculture points out. It signals a process to correct.
Each Annex I criterion comes with a sampling plan and limits. Four letters are enough to read it.
| Letter | Meaning | Example |
|---|---|---|
| n | Number of units making up the sample | n = 5: five units analysed |
| c | Number of units allowed between m and M | c = 0: no unit allowed above m |
| m | Limit below which the result is satisfactory | Absent in 25 g, or 100 cfu/g |
| M | Limit above which the result is unsatisfactory (three-class plans) | For example, a maximum value in cfu/g |
In a two-class plan (c = 0), a single unit above m makes the result unsatisfactory. In a three-class plan, the result is acceptable as long as no more than c units lie between m and M and none exceeds M. The French Ministry of Agriculture states that, failing any other choice, the default plan for hygiene criteria is n = 1, interpreted as two classes.
Three pieces of information on the report govern the reading: the unit (cfu/g, cfu/cm², presence in 25 g), the method (EN/ISO reference method or alternative method validated to EN/ISO 16140) and the wording “not detected” or “below the limit of quantification”, which do not mean the same thing.
Regulation (EU) 2024/2895 amended the criterion applicable to ready-to-eat foods able to support the growth of Listeria monocytogenes. Since 1 July 2026, the “absence in 25 g” criterion no longer stops when the product leaves the manufacturing site: it applies throughout the shelf life.
A product in which Listeria is detected during its shelf life remains compliant only if the manufacturer demonstrates that the bacterium will not exceed 100 cfu/g until the end of shelf life. Without this demonstration, for example a challenge or durability study, the result is unsatisfactory. Source: AGRINFO.
Article 7 of the regulation distinguishes the two families of criteria, but in both cases requires the cause to be investigated.
From unsatisfactory result to decision
Schematic diagram. The decision remains that of the operator and its quality teams.
The regulation also requires trends in results to be analysed: when a trend approaches unsatisfactory results, the operator takes action without undue delay (Article 9). This is often where manual monitoring reaches its limits: a drift shows over twelve months, not in a single report.
Frequency is set by the operator in its HACCP procedures, except where Annex I lays down a specific frequency; it may be adapted to the size of the business provided food safety is not endangered (Article 4(2)). How to build it is detailed on the page on the sampling plan, and how to integrate it in the quality control plan.
On the laboratory side, check that the scope of accreditation covers the methods requested and that the limits of quantification are compatible with your criteria. The food testing laboratory page details these selection criteria.
The Laboratory analyses module builds in Regulation (EC) 2073/2005 in its version of 1 July 2026, maintained by Tracklab. Each result received, from a supplier or a commissioned laboratory, is compared with this regulation and your own thresholds; the status (compliant, alert, non-compliant or “to be determined”) is displayed next to the laboratory's conclusion, with the threshold, regulation, version and date applied. Tracklab calculates and traces; the decision on the product remains that of your quality teams. See test report compliance.
What changes when microbiology results are compared and kept as a history in one place.
Without a tool: Criterion and sampling plan re-read for every report
With Tracklab: Result compared with built-in 2073/2005 and your thresholds
Without a tool: Trends rebuilt by hand before the review
With Tracklab: History per parameter, product and supplier
Without a tool: Decision noted in a spreadsheet or an email
With Tracklab: Status, threshold, version and date kept for the audit
The situation, the calculation of re-keying time and a four-step demonstration of the Laboratory analyses module.
Regulation (EC) 2073/2005 requires operators to comply with the Annex I criteria and to perform testing as appropriate when validating or verifying their HACCP procedures. The frequency is set by the operator, except where Annex I lays it down.
A food safety criterion assesses the acceptability of a product or batch placed on the market. A hygiene criterion assesses how the process is working and does not apply to products placed on the market; exceeding it calls for corrective action.
The bacterium tested for was not detected in a 25-gram test portion, using the method stated. It is a qualitative result, different from a count in cfu/g.
Since 1 July 2026, for ready-to-eat foods able to support its growth, the “absence in 25 g” criterion applies throughout the shelf life, unless the manufacturer demonstrates that the bacterium will not exceed 100 cfu/g (Regulation (EU) 2024/2895).
No. Tracklab neither samples nor analyses. The Laboratory analyses module gathers the reports received from your suppliers and laboratories, compares them with Regulation 2073/2005 and your thresholds, and traces each calculated status.
Bring three real reports: we run the compliance calculation against your criteria during the call.
0.02 mg/kgCompliant0.09 mg/kgAlert0.015 mg/kgNon-compliantAbsent /25 gTo be determinedIllustration, fictitious data.
Their quality and purchasing teams collect, control and leverage their supplier data with Tracklab.
companies supported
suppliers referenced
products and ingredients
“Tracklab has eliminated the blind spots that existed in our document monitoring. Every document is analysed, every change is detected and every decision is traceable. This has enabled us to take a real step forward in terms of professionalism and credibility, particularly with auditors and customers.”